Kangaroo joey, Loading & rinsing of feeding pump, Enteral feeding & flush pump
Advertising
Tips for Home Tube Feeding Safety. How to Burn More Calories Every Day. Dietitians about your question. She wrote back: “The feed and flush sets look pretty much the same as the single Joey feeding sets, albeit with 2 bags and 1 common tube that attaches to the pump. Also the Covidien Kangaroo Pump user manual as a PDF is online here. Battery of the Kangaroo Joey feeding pump. Use only the supplied power adapter to charge your Kangaroo Joey feeding pump from an AC power source. Use only Kangaroo Joey Enteral Feed and Flush Pump with Pole Clamp A/C Power Adapter (with built-in A/C adapter) with pump. See Section XIII - Service Part Numbers for replacement of A/C Power Adapter. The Kangaroo™ Joey enteral feeding pump 'ATM style' interface guides the user through programming. It recognizes the type of pump-set that is loaded then asks the user questions appropriate only to that set. This makes it easy to program, use and in-service allowing more patient interaction. Pump Set Based Program. Pump set based programming.
Kangaroo Joey
The Kangaroo Joey pump is another portable pump, the newest pump from a company that has been making feeding pumps for years. It is somewhat larger and thicker than the Zevex Infinity pump, weighing 1.7 pounds and measuring 4.1 inches by 5.1 inches by 3.6 inches.
™
Enteral Feeding & Flush Pump
Loading & Rinsing of Feeding Pump
Do not use feeding sets for longer than 24 hours.
Proper loading & unloading of a feeding set
Proper rinsing of the feeding set
1) Feed & flush valve assembly, 2) Feed only valve
assembly, 3) Distal end of feeding set, 4) Pump
1) Grasp thumb tab on valve and insert into left
Enteral Feeding Pump
pocket, ensure valve is fully seated. Thumb tab
should align with slot in blue door.
2) Grasp black ring retainer, gently wrap tubing
around rotor, and insert retainer directly into
right pocket.
right pocket.
Do not overstretch tubing.
1) Disconnect feeding set from patient before rins-
ing. The feeding set must remain loaded during
the rinsing procedure.
2)
CAUTION-
if set is removed from the pump,
it may damage the set and prevent use and will
negativley effect the system accuracy.
1
2
3
4
3) To properly unload a pump set, power the
pump off and wait 10 seconds before removing
the feeding set.
3) Empty contents of feed bag.
4) Fill the feed bag with water to approximatley
half of the total capacity. Properly seal the bag
and shake for 5 to 10 seconds.
Advertising
Popular Brands
Popular manuals
How To Use Feeding Pump
Advertising
Battery Operation
Unplugging the pump from the AC line will automatically put the pump on battery power. To recharge
the battery, plug the pump into an AC wall outlet. Pump will automatically begin charging.
the battery, plug the pump into an AC wall outlet. Pump will automatically begin charging.
General Instructions
1. Fill or spike feeding container prior to setting up pump.
2. Turn pump on – Press Power button in lower right-hand corner.
3. In order to achieve proper accuracy, the fluid line in the feeding set bag must be 6 inches
2. Turn pump on – Press Power button in lower right-hand corner.
3. In order to achieve proper accuracy, the fluid line in the feeding set bag must be 6 inches
above the top of the feeding pump, when initiating the feeding cycle.
4. Select
}
“Keep Settings” or
}
“Clear Settings” (for day to day use with the same feeding
Mitsubishi ductless air conditioner manual. regimen the
}
“Keep Settings” option should be selected).
5. Load the Feeding Set per diagram. Do not overstretch the tubing.
Priming the Pump
1. Press
}
“Prime Pump” to access the pump priming options.
2. Press
}
“Auto Prime” to automatically prime the pump set. The Pump will quickly prime the
feed line and stop the formula before reaching the end of the line.
3. Press the
}
“Hold To Prime Feed” menu selection to carry formula to end of tubing.
4. Press
}
“Done'.
![Manual Manual](/uploads/1/2/5/3/125302209/866189606.jpg)
Setting the Feed Rate
1. Select
}
“Adjust Feed” then
}
“Feed Rate” use the buttons on the left to program the pump from
1 to 400 in increments of 1ml. Select
}
“Enter” when desired rate is set.
2.
Select
}
“Run”. You will notice a small drop scroll down the screen when running.
Re-Priming the Pump After the Feed Bag Empties
1. A pump set bag that has been emptied will trigger the Feed Error screen. In this condition the pump
set bag can be refilled to continue the feeding, but only after the pump set has been re-primed.
2. Disconnect the feeding line from the patient.
3. Refill the bag.
4. Press
3. Refill the bag.
4. Press
}
“Continue” to begin the pump Running.
5. Press
}
“Hold', then press
}
“Adjust Settings”, then press
}
“Prime Pump”.
6. Press
}
“Hold To Prime” to prime the line. (Do Not Use Auto Prime)
7. Press
}
WARNING: The Sony Reader must be fully charged before installing this update. Sony portable reader system prs-505 manual.
“Done”, then select
}
“Run”
![Joey Home Feeding Pump User Manual Joey Home Feeding Pump User Manual](/uploads/1/2/5/3/125302209/559207595.jpg)
Kangaroo Joey Feeding Pump Instructions
To Change Rate or Clear Volume
1. Select
}
“Hold”.
2. Select
}
“Clear Vol Fed” to clear the volume.
3. Select
}
“Adjust Settings” to adjust all settings.
4. Select
}
“Run” to return to normal operations.
Pump sets should not be reused after 24 hours of initial usage.
Kangaroo
™
Joey Enteral Feeding Pump
EZ Mode Operation “Feed Only Set” Directions For Use